WinDaq ExcelLink

Levertijd:
2~7 dagen
SKU
WinDaqExcelLink

WinDaq-to-Excel Real Time Link

●  Supports 32- and 64-bit version of MsExcel
●  Supports ChannelStretch
●  Up to 160Ks/s, real time logging to Ms Excel
●  Powerful trigger methods:
Window Trigger to capture data in- or outside a range
Slope Trigger to capture data when reading crossing a point
Event Trigger to capture single row when an event happens
Derivative Trigger to trigger on rate of change, such as a glitch
Paced Trigger to capture a single row at predefined pace
Delayed Trigger to capture data after a predefined delay 
Manual Trigger to capture data based on manual operation
Digital Channel Trigger to capture data based on digital input conditions
●  Use Excel Template to perform analysis and add time stamps automatically
●  Capable of recording to both Excel and WinDaq files simultaneously
●  No programming needed

 

Description
WinDaq ExcelLink (short for WinDaq Advanced Trigger ExcelLink) is a bridge between WinDaq software and Microsoft Excel.

It provides real-time conection to Excel spreadsheet (32- or 64-bit) and can stream data to Excel spreadsheet at high speed. Four trigger methods are provided - two-point Windows trigger, one-point slope trigger with pre- and post-trigger data, manual single row and block trigger, and programmable event driven single-row trigger.

Even though Excel can store over 1,000,000 rows of data, it is still a small buffer for high speed data aquisition unless trigger modes are utilized so that only data of interests is captured. ExcelLink supports advanced math to construct various trigger methods and every data point in WinDaq is examed when evaluating the trigger conditions. Window Trigger can capture signals inside or outside a range within two predefined start/stop conditions. Slope Trigger with pre- and post- trigger can capture signals before and after a predefined trigger point. Event trigger can capture signals at the moment trigger conditions are met. Derivative Trigger can capture rate of change, or glitch. Paced Trigger capture data at predefined interval. Delayed Trigger can capture data at a predefined time after the trigger condition is met. Manual Trigger can capture signals at operator's key instruction.

 

Windaq ExcelLink is compatible with Dataq Instruments Models:

  • DI-1100
  • DI-245
  • DI-2008 Series
  • DI-2108 Series
  • DI-4108 Series
  • DI-4208 Series
  • DI-4718-B Series
  • DI4730
Meer informatie
Art.nr.
WinDaqExcelLink
Fabrikant
Dataq Instruments
Mijn vraag gaat over: WinDaq ExcelLink
To Top