● Provides four floating 16-bit analog outputs with 750 VDC isolation. Controls analog devices without ground loops. ● Four differential analog inputs with programmable ranges. Scalable inputs for reading voltage sources, current shunts, sensors etc. ● User setable scale factors for all analaog singals. Matches 2361A commands and data to real values. ● High current drivers can operate external relays etc. Digital control of external devices. ● Digital inputs read or monitor external signals. Generates Service Request Message on selected signal changes. ● RS-485 network capability. Supports multiple units on one RS-485 network. ● Includes sample control, calibration and configuration programs. Complete software package.
ICS Analog Interface Module 2361A is a compact, RS-232/RS-485 to Analog Interface that provides signals for controlling analog devices over a serial path. The Model 2361A has four floating analog output channels, four differential analog inputs, digital output drivers and digital inputs. The analog values can be scaled to match the physical values of the input signals or of the controlled parameters. The scale factors and all other user set confi guration parameters are saved in Flash memory until changed. The 2361A's serial interface provides the functionality of a GPIB interface with control from any PC's COM port or over a RS-485 network. The ICS Analog Interface Module 2361A accepts both industry standard SCPI commands and easy-to-use short form commands. Typical ICS Analog Interface Module 2361A applications are controlling power supplies, providing analog stimuli or measuring analog signals.
Provides RS-232 full duplex and RS-485 (RS-422) half duplex asynchronous serial interfaces. Unit automatically responds to the serial interface that receives the command.
RS-232 Interface
Signals
AB, BA and BB
Mode
Full Duplex
RS-485 (RS-422) Interface
Signals
TX/RX pair
Mode
Half duplex with or without address detection
Addresses
0 to 15
Termination
220 Ω load resistor and 1 KΩ pullup/pulldown
Common Specifications
Baud Rate
1200 to 38.4 Kbaud
Data Bits
7 or 8
Stop Bits
1 or 2
Parity
Odd, Even or None
Command Sets